As a tenant, you are responsible for a small set of routine maintenance tasks that keep your home safe and efficient. Staying on top of these helps prevent costly repairs and protects your security deposit.
π© Found something beyond your responsibility?
Submit a Maintenance Request βπ Table of Contents
- ποΈ Monthly Tasks β filter, detectors, lint trap, under-sink checks
- π Fall / Pre-Winter β hose bibs, batteries, fan direction, pipe freeze prevention
- πΈ Spring Tasks β hose bibs back on, fan direction, AC test
- π° How to Winterize Hose Bibs β full step-by-step
- π§ As-Needed Tasks β drains, locks, fridge coils
- π Owner’s Responsibility β what to submit a request for
ποΈ Monthly Tasks
Inspect the HVAC Air Filter (replace per the property-specific schedule)
A clogged filter is the a common cause of AC and heating breakdowns. It also increases your energy bills and reduces air quality. β See the HVAC Guide β Air Filter section for step-by-step instructions.
- 1-inch filters Every 60 days
- 2- or 3-inch filters Every 90 days
- 4β5-inch media filters Every 120 days
- Pets / Allergies / Dusty home Replace sooner if dirty, wet, damaged, or restricting airflow
Test Smoke and Carbon Monoxide Detectors
Clean Dryer Lint Trap
Clean the lint trap before every load. A clogged lint trap is the leading cause of dryer fires. Once a month, rinse the screen under warm water β if water pools on it, fabric softener residue has built up and the screen needs cleaning. β See Appliance Guide β Dryer Not Drying if your dryer is also underperforming.
Check Under Sinks for Leaks
Clean Dishwasher Filter
π Fall / Pre-Winter Tasks
Complete these before the first freeze. Northern Virginia’s first freeze is typically mid-November, but cold snaps can arrive as early as late October.
Winterize Outdoor Hose Bibs
Tenant responsibility. Failure to winterize can cause burst pipes and significant water damage β costs that are your responsibility. β See the full Winterizing Hose Bibs section below.
Replace All Smoke and CO Detector Batteries
Reverse Ceiling Fan to Winter Mode
Check Door and Window Weatherstripping
Protect Against Frozen Pipes
- Keep thermostat at least 55Β°F at all times β never turn heat off entirely in winter.
- On very cold nights, open cabinet doors under sinks on exterior walls.
- Away for more than a few days in winter? Notify us so we can check the property.
- β See Plumbing Guide β Frozen Pipes if pipes do freeze.
πΈ Spring Tasks
Complete these in late March or April, once freezing weather has passed for the season.
Reverse Hose Bib Winterization
- Confirm all outdoor faucets are closed (clockwise / off).
- If you closed an indoor shut-off valve, slowly open it by hand. Do not force a stuck valve. If you did not close one, skip this step.
- Check each hose bib for drips or leaks. β Any leaks or low pressure β submit a maintenance request before connecting hoses.
Reverse Ceiling Fan to Summer Mode
Test AC Before Hot Weather Arrives
Many systems should not be run in cooling mode when it is cold outside, and the minimum outdoor temperature varies by model, so check your manual or ask us before testing. When it is warm enough, set to COOL a few degrees below room temperature and wait 15β20 minutes. If ice forms, turn cooling off and report it. β Not cooling or making unusual noises? Submit a maintenance request now β technician availability is limited in summer. See HVAC Guide β AC Not Cooling for full diagnosis.
Clean Window Tracks and Screens
π° Winterizing Hose Bibs (Step-by-Step)
Step 1: Disconnect All Attachments
- Remove all hoses, splitters, sprinkler timers, and nozzles. Even frost-free faucets can’t drain with a hose attached.
- Drain hoses completely, coil, and store indoors (garage, shed, or utility closet).
Step 2: Find the Indoor Shut-Off Valve
Step 3: Close the Shut-Off Valve
- Ball valve (lever handle): Turn perpendicular (90Β°) to the pipe to close.
- Gate valve (round handle): Turn clockwise until it stops. Don’t over-tighten.
- β Valve feels stuck or very hard to turn β do not force it. Submit a maintenance request.
Step 4: Open and Drain the Outdoor Faucet
- If you closed an indoor shut-off for that faucet, go outside and open the hose bib fully (counter-clockwise). Water will trickle briefly as the line drains β this is normal. Let it drain completely.
- Leave the outdoor faucet open only if you closed an indoor shut-off for it, so residual water can drain rather than freeze. If there is no indoor shut-off for that faucet, leave the faucet closed with a foam cover on it. If you are unsure which applies, ask us before winter.
Step 5: Add Foam Cover (Optional but Recommended)
- Dripping after shutoff Shut-off valve not fully closed or damaged. Submit a request before freezing weather.
- Valve has a bleeder cap Do not touch the cap. Tell us and we will handle it.
- Water stains near hose bib in spring Pipe may have cracked over winter. Submit a request immediately.
π§ As-Needed Tasks
Keep Drains Clear
Lubricate Door Locks
Refrigerator Coil Cleaning
Report Issues Promptly
Small issues β a slow drip, a stiff door, a flickering light β are almost always cheaper and easier to fix early. Delayed reporting of known issues can affect your security deposit and lease standing. When in doubt, submit a request.
π What Is the Owner’s Responsibility
- Weatherstripping, caulking, or door/window seals β damaged, missing, or deteriorated β Locks Guide
- Dryer vent duct cleaning (exterior duct β tenant handles lint trap only) β Appliance Guide
- Smoke and CO detector replacement (end-of-life or not working after battery replacement) β Detector Guide
- HVAC servicing, refrigerant, or any mechanical failure beyond filter replacement β HVAC Guide
- Any plumbing repairs, leaks, or pipe issues β Plumbing Guide
- Pest control involving structural defects, unrepaired entry points, plumbing/drainage problems, or common areas (ordinary pests like ants, mosquitoes, and occasional wildlife are the tenant’s routine responsibility after the first 30 days β see Tenant Guide)
- Lock re-keying or replacement (always through NOVA RPM) β Locks Guide
π© Submit a Maintenance Request
Found an issue that’s beyond your responsibility as a tenant? Include the exact location, when it started, what you tried, and safe photos for the fastest response. Please do not include door codes or passwords.
Submit a Maintenance Request βOr contact us: π 571-946-6021 | π§ maintenance@novarpm.com