Your HVAC system controls heating and cooling. Most issues can be resolved with simple checks. Start with the symptom that best matches what you see β sections are ordered from most critical to least.
π© Ready to skip ahead?
Submit a Maintenance Request βπ Table of Contents
- β‘ System has no power at all / Thermostat is completely blank
- βοΈ AC not cooling β thermostat has power but no cool air
- π₯ Heat not working β thermostat has power but no warm air
- π Unusual noises β rattling, squealing, grinding, hissing
- π‘οΈ Uneven temperatures β hot or cold spots in certain rooms
- π‘ High energy bills
- π Air filter maintenance
- π‘οΈ Thermostat display issues
- π§ Humidity & air quality
β‘ HVAC Has No Power / Won’t Turn On
- Check the thermostat display. If it is blank or dim, replace the batteries first (most use 2 AA or AAA batteries). β If this restores the display, skip to AC Not Cooling or Heat Not Working.
- Check the circuit breaker(s). Look for breakers labeled “AC,” “Air Conditioner,” “Furnace,” or “Air Handler.” There may be two separate breakers. If tripped (middle position), flip fully OFF then back ON one time only. Wait 5 minutes. β If the breaker trips again, do not reset it again β submit a maintenance request.
- Check the furnace or air handler power switch. Often a light-switch-style switch on the side of the unit. Make sure it is ON.
- Look for water near the unit. A full condensate drain pan can trigger a safety float switch that shuts the system off. This is a visual check only. A full drip tray triggers a safety float switch that shuts the system off. If you see water, do not empty pans, vacuum the drain line, bypass the float switch, or restart the system. β If there is water in or around the unit, do not restart β submit a maintenance request immediately to prevent water damage.
β Tried everything above?
Submit a Maintenance Request ββοΈ AC Not Cooling
Match your symptom below β click the one that fits and skip directly to those steps.
- No Power Thermostat is blank β go to power section first
- No Response Thermostat has power but nothing starts
- Partial Indoor unit runs but outdoor unit is silent
- Both Running Both units running but home isn’t cooling
- Ice/Weak Air Ice on unit or copper lines / weak airflow
No Power Thermostat is blank or has no power
β Go to HVAC Has No Power / Won’t Turn On above and follow those steps first.
No Response Thermostat has power but nothing happens when set to COOL
- Verify thermostat settings. Mode = COOL, set temp lower than room temp, fan = AUTO. Wait 5 minutes β there’s a built-in startup delay.
- Check both circuit breakers (indoor air handler + outdoor condenser β may be separate). Reset a tripped breaker one time only. β If it trips again, stop β submit a maintenance request.
- Check the air handler power switch on the side of the unit β make sure it is ON.
- Look for water near the unit. A full condensate pan triggers a safety shutoff. This is a visual check only. If you see water, do not empty pans, vacuum the drain line, bypass the float switch, or restart the system. β If there is water in or around the unit, do not restart β submit a maintenance request.
Partial Indoor unit runs but outdoor unit is NOT running
- Check the outdoor breaker at your panel. Do not open, pull, or reset the disconnect box near the condenser. If it looks damaged or loose, report it.
- Check for ice on the outdoor unit or refrigerant lines. β If you see frost or ice, go to AC Freezing Up for safe thaw steps.
- Let it rest. The outdoor unit has a 5β10 minute built-in delay after startup to protect the compressor. Turn off AC, wait 10 minutes, restart.
- If still not starting: β Submit a maintenance request. Note whether you hear any humming from the outdoor unit.
Both Running Both units are running but home isn’t cooling
- Inspect the air filter. A clogged filter is a common cause of poor cooling. Replace if dirty β size is printed on the filter edge.
- Check all supply vents β open and unblocked by furniture or curtains.
- Check for ice on indoor coils or copper lines. β If you see frost or ice, go to AC Freezing Up immediately.
- Look at the outdoor condenser. Clear loose debris and plants within 2 feet and check that the fan is not blocked. Never reach into the unit or remove its panels.
- Check for water near the indoor unit. Active leaking = turn off AC and submit a maintenance request.
- Very hot days: The system may struggle to keep up. If the indoor temperature keeps rising, or the air from the vents does not feel cooler than the room, report it. Ceiling fans and closed blinds can help in the meantime.
When submitting your request, include: thermostat setting and mode, current indoor temperature, whether the outdoor unit is running, and photos of any ice, water leaks, or error codes.
Ice / Weak Air Ice on the unit or copper lines / Weak airflow
Turn cooling OFF immediately. Do NOT leave it on COOL while frozen. If there is no water leaking and no electrical concern (no sparks, burning smell, or wet electrical parts), you may set the fan to ON to help the ice melt. Otherwise turn the system off at the thermostat and report it.
- Let it thaw completely β 2β24 hours depending on ice buildup. Place towels near the air handler to catch dripping water.
- While it thaws: replace the air filter and open all supply and return vents fully.
- Once fully thawed, restart on COOL and watch it for 30 minutes. If ice returns, turn cooling off and report it. Do not keep restarting the system. β If ice forms again, including after replacing the filter and opening vents, a technician needs to find the cause β submit a maintenance request.
π₯ Heat Not Working
- No Power Thermostat is blank β go to power section first
- No Response Thermostat has power but furnace won’t start
- Clicking You hear clicking but no heat comes out
- Blower Running Blower runs but air isn’t warm
No Power Thermostat is blank or has no power
β Go to HVAC Has No Power / Won’t Turn On above and follow those steps first.
No Response Thermostat has power but furnace doesn’t start
- Verify thermostat settings. Mode = HEAT, set temp higher than room temp. Wait 5 minutes.
- Check the circuit breaker for the furnace or air handler. Reset a tripped breaker one time only.
- Check the furnace power switch (light-switch on side of unit) β must be ON.
- Check the furnace filter. A severely clogged filter causes the furnace to overheat and shut off. Replace if dirty, wait 30 minutes, try again.
- Check that all vents are open. Too many closed vents creates back-pressure and shuts the system down.
Clicking You hear clicking but no heat comes on
- Gas furnaces: look, but do not relight. If you hear clicking with no ignition, the igniter may have failed. Do not relight a pilot light or open the furnace panels. Note any model information or error light pattern you can read without opening the unit, and include it in your request.
- Do not adjust gas valves. If other gas appliances are also not working and you do not smell gas, contact your gas utility. Otherwise report the problem.
- β If you smell gas (like rotten eggs) or hear hissing from a gas line, leave the home immediately. Do not use switches or phones inside. Call 911 and your gas utility from outside. If clicking continues without ignition and there is no gas smell, report it.
Blower Running Blower runs but air isn’t warm
- Wait 5β10 minutes. The blower sometimes starts before burners fully heat the heat exchanger.
- Check the filter. A clogged filter trips the high-limit switch, running the blower to cool down while keeping burners off.
- Check the thermostat fan setting. If fan is set to ON instead of AUTO, it blows continuously β including when not heating β producing cool air.
β Tried everything above?
Submit a Maintenance Request βπ Unusual Noises from HVAC
- Grinding Turn off immediately β failing motor, can cause complete breakdown. Submit a maintenance request.
- Squealing / Screeching Turn off immediately β worn blower belt or failing bearing. Submit a maintenance request.
- Hissing Possible refrigerant leak or high-pressure issue. If you smell gas, leave the home and call 911. Otherwise turn off the system and submit a maintenance request.
- Clicking repeatedly without starting Faulty relay or igniter. See Clicking but no heat. Submit a maintenance request.
- Rattling / Vibrating Check vent covers for loose screws. Check if anything fell into a vent. If from air handler or outdoor unit, submit a request.
- Banging / Popping on heat startup Usually normal duct expansion as metal heats up. If very loud or frequent, report it.
π‘οΈ Uneven Temperatures / Hot or Cold Spots
- Check all vents are open and unobstructed in problem rooms.
- Check for air leaks around windows and doors. Use draft stoppers or weatherstripping.
- Adjust vent dampers. The lever on supply vents adjusts airflow. In summer, close vents slightly in cooler rooms; in winter, close vents in warmer rooms.
- Use ceiling fans. Counter-clockwise in summer (cooling downdraft), clockwise at low speed in winter (pushes warm air down). Small switch on motor housing reverses direction.
π‘ High Energy Bills
- Replace a dirty air filter β a clogged filter forces the system to run longer.
- Set reasonable temperatures: 68β72Β°F in winter, 74β78Β°F in summer when home; 65Β°F / 80Β°F when away.
- Use a programmable thermostat schedule if available.
- Seal drafts around windows and doors.
- Close blinds and curtains in summer to block solar heat gain.
- Ensure the outdoor AC unit is clean and has 2 feet of clearance.
π Air Filter Maintenance (Tenant Responsibility)
Changing the air filter is a tenant responsibility. A dirty filter is a common cause of AC and heating problems. It also increases energy bills and reduces air quality.
How to change your filter:
- Locate the filter β in a return air vent on the wall/ceiling, or inside the air handler near the blower.
- Turn the system OFF before changing the filter.
- Note the filter size printed on the old filter edge (e.g., 16x25x1). Buy the exact same size.
- Check the airflow arrow on the new filter β it must point toward the air handler (away from the return duct).
- Slide in the new filter and close the compartment. Turn the system back on.
- 1-inch filters Every 60 days
- 2- or 3-inch filters Every 90 days
- 4β5-inch media filters Every 120 days
- Pets / Allergies / Dusty conditions Replace sooner if dirty, wet, damaged, or restricting airflow
π‘οΈ Thermostat Issues
- Blank or dim display: Replace the batteries (most use 2 AA or AAA). β If this works, return to AC Not Cooling or Heat Not Working for next steps.
- Unresponsive after battery replacement: Check the circuit breaker. If breaker is on and thermostat still doesn’t respond, submit a maintenance request.
- Temperature reads incorrectly: Make sure it’s not in direct sunlight, near a vent, or near a lamp. If consistently wrong by 3β4Β°F+, submit a maintenance request.
- Do not tamper with the wiring behind the thermostat.
How to Replace Thermostat Batteries
Most thermostats take 2 AA or AAA batteries, but where they’re located depends on the model. Use whichever method matches your unit:
- Thermostats with a visible battery slot: Look for a small door or panel on the front, bottom, or side of the thermostat. Slide, flip, or pop it open, note the polarity (+/-) of the old batteries before removing them, insert the new batteries the same way, and close the panel.
- Thermostats that must be pulled off the wall: If there’s no visible battery door, the thermostat body may unclip from its wall-mounted base plate. Only do this if the manufacturer instructions or a visible release tab say it comes off. Grip the outer edges (not the screen) and pull gently straight toward you. If it does not release easily, stop and submit a request. Never touch or disconnect wires. Once it’s off, the battery compartment will be on the back. Swap the batteries, then press the thermostat firmly back onto the base plate until it clicks securely into place.
- Not sure which type you have? Check the edges of the thermostat for a seam or small notch, which usually means it pulls off the wall. If you instead see a small door, sliding cover, or battery icon on the face of the unit, it opens in place.
- Always replace with fresh batteries of the correct size, and avoid mixing old and new batteries.
π§ Humidity & Air Quality Issues
Too humid (sticky, condensation on windows):
- Run the AC β it naturally dehumidifies as it cools.
- Run exhaust fans in bathrooms and kitchen during and after use.
- Ensure the dryer vent exhausts outside, not into the home.
- If humidity stays above 60%, submit a maintenance request β excess moisture causes mold.
Too dry (static electricity, dry skin, nosebleeds):
- Use a portable humidifier in bedrooms as needed. Ideal indoor humidity is 30β50%.
- If the home has a whole-home humidifier attached to the furnace, contact us about its maintenance.
π© Submit a Maintenance Request
You can submit a request at any time, and right away if anything is unsafe, you cannot do a step, or you are unsure. Helpful details: thermostat mode and setting, current indoor temperature, whether the outdoor unit is running, when the problem started, whether it is constant or on and off, what you tried and the result, any water, smell, or noise right now, and safe photos or video of ice, leaks, error codes, or the equipment label.
Submit a Maintenance Request βOr contact us directly: π 571-946-6021 | π§ maintenance@novarpm.com